beautypg.com

Peerless Lighting CLM9 - T5_T5HO User Manual

Contrail linear, Indirect-direct t5/t5ho, Suspended

background image

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

LAMPING OPTIONS

DESIGN GUIDELINES

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Contrail” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T5/T5HO

CLM9  Contrail Linear

Examples:

CLM9 2 28T5 COA 40FT R8 277 GEB10 SCT LP835 F1/18 — CLM9 2 54T5HO COA 32FT R8 277 GEB10 1SE EL SCT LP835 F1/21

Suspended

CLM9

Contrail Linear

Indirect-Direct T5/T5HO

6”

3”

CLM9 - 2

Because the shielding (diffuser) is fully luminous,

color variations in the lamp may create subtle

fluctuations in the color of the shield.

If dual switching is required for energy savings,

dimming or the alternating lamp circuit switching

option (ALC) is recommended in place of the dual

circuit switching option (DCT). DCT will switch

each side of a luminaire row separately which will

affect the uniform luminous aesthetic of the lens.

ALC will switch every other 4’ section of a luminaire

row separately.

Construction

Die-formed pre-painted steel housing. Extruded

aluminum fillers. Die-cast aluminum end caps.

Highly specular aluminum end plates.

Shielding

GrateOptic curved, crenulated diffuser is extruded

opal acrylic.

Reflectors

Die-formed, highly specular aluminum reflector has

a minimum 98% reflectance.

Finish

Fine-textured, white polyester powder paint is

standard on the fillers and end caps.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

4’, 8’, and 12’ individual luminaire sections for

nominal suspension spacing of 4’, 8’ and 12’. Add

3

5

8

” for each end cap to determine total luminaire

length. Using internal joiners, 4’, 8’ and 12’ sections

can be joined to form longer length luminaires.

__________

__________

__________

__________

_________

__________

__________ __________

__________

__________

Luminaire

CLM9

# of

Lamps in

Cross

Section

2

Lamp Type

28T5 28W T5

54T5HO 54W T5HO

Shielding

COA Crenulated

opal

acrylic

Luminaire

Row

Length

X FT

(4’ increments)

Maximum

Section

Length

R4

4’ section(s)

R8

8’ section(s)

R12

12’ section(s)

Voltage

120

277

347

2

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

3

(Blank) None

EC

Emergency circuit

EL

1,4

Emergency battery

pack

EN

1,4

Emergency battery

pack w/night light

circuit

______________

________________

______________

______________

_________________________________

Switching

5

SCT

Single circuit

ALC

Alternate lamping

module circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+ CRI Premier

LP835P 3500K 80+ CRI Premier

LP841P 4100K 80+ CRI Premier
Reference

Lamp Chart

on website or

consult factory for other options.

Mounting Type /

F1/

T-bar ceiling (universal

mounting bracket)

F1A/ T-bar ceiling (UMB with

integrated J-box)

F2/

Hard ceiling (horizontal J-box)

Overall Suspension

12 12”

15 15”

18 18”

21 21”

24 24”

XX XX”
Overall suspension is

measured from ceiling to

bottom of luminaire.

Options

ACG

Adjustable cable grippers

BLK

Black cord, cord manager and canopy

DL

Damp location label

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2

Emergency through wiring w/single feed, separate neutrals

GLR

Fusing (fast blow)

GMF

Fusing (slow blow)

MCS

Matching feed canopy at support

NEPP5D nLight enabled control module per row/zone

OJB

Offset junction box

SLP

Sloped ceiling (for 10-45°, must be specified with F2, ACG and

OJB options)

XXXX Integrated sensor; choose options and obtain code on page 2

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

3 Emergency type is installed in last 4’ of luminaire sections.

Separate feed required unless ELS or ELS2 is specified

4 Option EL or EN (Battery Pack) is :

a. not permitted with dimming in the same row

b. must be in the same section as the lamp being operated

c. not permitted in a 4’ section

d. limited to one battery pack per section

5 SCT with or without dimming, or ALC is recommended

over DCT. DCT and ALC are not available with dimming