Peerless Lighting OR1W1 - T5_T5HO User Manual
Origami wall, Indirect t5/t5ho, Wall mount
LAMPING OPTIONS
S P E C I F I C A T I O N S
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
CATALOG NUMBER
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
SPECIFICATIONS
OR1W1 - 1
OR1W1 - 2
OR2W1 1T5
OR2W1 2T5
3
3
⁄
4
”
3
3
⁄
4
”
8
3
⁄
8
”
8
3
⁄
8
”
1’
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
Indirect T5/T5HO
OR1W1 Origami Wall
Origami Wall
Indirect T5/T5HO
Construction
Formed aluminum housing creates a 8
3
⁄
8
” x 3
3
⁄
4
”
body. Die-cast aluminum end caps are mechanically
attached with no exposed fasteners.
Reflectors
White, high-reflectance reflector and hammer
tone aluminum reflector with prismatic acrylic
kicker lens.
Finish
Aluminum powder paint housing with gloss
white end caps and joiners OR gloss white, red
or black housings with aluminum powder paint
end caps and joiners. Consult factory for custom
color requirements.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’ and 8’ nominal luminaire sections. Nominal
4’ lamp modules are 46
1
⁄
2
”. Add
3
⁄
4
” for each end
cap to determine total luminaire length. Using
joiners, 4’ and 8’ sections can be joined to form
longer rows.
Eco-friendly Packaging
100% post-consumer recycled cardboard box,
100% recycled cardboard cradles and kraft paper
tape. Biodegradable, protective luminaire bag.
Examples:
OR1W1 2 28T5 24FT R8 277 GEB10 DCT LP835 C110 — OR1W1 2 28T5 40FT R8 277 GEB10 1SE EL SCT LP835 C301
Wall Mount
OR1W1
Elevation
Notes:
1 Not available in 347V
2 Not available with 28T5 lamps
3 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
__________
__________
__________
_________
__________
__________ __________
__________
__________
Luminaire
OR1W1
# of Lamps in
Cross Section
1
2
Lamp Type
28T5 28W T5
54T5HO 54W T5HO
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1,2
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
OSDIM
1,2
Osram 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
Emergency Type
3
(Blank) None
EC
Emergency circuit
EL
1
Emergency battery pack
EN
1
Emergency battery pack
w/night light circuit
______________
________________
______________
_________________________________
Switching
SCT
Single circuit
DCT Dual circuit
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+ CRI Premier
LP835P 3500K 80+ CRI Premier
LP841P 4100K 80+ CRI Premier
Referenc
factory for other options.
Finish
C032 White white (high gloss)
C110 Painted aluminum (low gloss)
C301 Black (gloss)
C302 Red (gloss)
C099 Custom finish
Options
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
NYC New York City code