Peerless Lighting NRM9 - T8 User Manual
Naro, Suspended, Nrm9
LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
S P E C I F I C A T I O N S
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710
•
Tel: 510.845.2760
•
Fax: 510.845.2776
•
•
Type:
________________________
Project:
______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms locat
T8
NRM9 Naro
Suspended
NRM9
Naro
T8
Examples:
NRM9 2 32 SPR FST 40FT R8 277 GEB10 DCT LP835 F1/18 C100 — NRM9 2 32 WHR FST 40FT R8 277 GEB10 1SE EL DCT LP835 F1/18 C100
Construction
Nominal 5
1
⁄
4
”W x 2
3
⁄
4
”H extruded aluminum
housing. Die-cast aluminum end caps are
mechanically attached with no exposed fasteners.
Reflectors
Semi-specular high reflectance aluminum or
high reflectance white painted steel. Select
semi-specular (SPR) for a wide distribution and
maximum row spacing. Select white (WHR) for
narrow applications (i.e. corridors) to soften side
wall shadows.
Shielding
Frosted acrylic diffuser.
Finish
White polyester powder painted or satin anodized.
Satin anodized consists of satin anodized housing
with end caps painted C110 (aluminum) to match.
Optional custom colors available, consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’ and 8’ lengths in a single section. For total
luminaire length add
1
⁄
2
” for each standard end cap.
Using internal joiners, 4’ and 8’ sections can be
joined to form longer rows.
Eco-friendly Packaging
100% post-consumer recycled cardboard box,
100% recycled cardboard cradles and kraft paper
tape. Biodegradable, protective luminaire bag.
NRM9 - 1
NRM9 - 2
5
1
⁄
4
”
5
1
⁄
4
”
2
3
⁄
4
”
2
3
⁄
4
”
__________
__________
__________
__________
__________
_________
__________
__________ __________
__________
Luminaire
NRM9
# of
Lamps in
Cross
Section
1
2
Lamp Type
32 T8
Reflector
SPR Specular
reflector
WHR White
Reflector
Shielding
FST Frosted
Diffuser
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4
4’ section(s)
R8
8’ section(s)
Voltage
120
277
347
Ballast Type
GEB10
<10% THD Electronic
ADEZ
1
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
ADZT
1
Advance Mark 7 0-10V dim
Referenc
or consult factory for other options.
# of Emergency
Modules
2
(Blank) None
1SE
1 section
2SE
2 sections
XSE
X sections
______________
________________
________________
______________
______________
______________
_________________________________
Emergency Type
2
(Blank) None
EC Emergency
circuit
EL
1
Emergency
battery pack
EN
1
Emergency
battery pack
w/night light
circuit
Switching
SCT
Single circuit
DCT Dual circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired
for energy
saving lamps.
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Referenc
website or consult factory
for other options.
Mounting Type /
F1/
T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/
Hard ceiling (horizontal
J-box)
Overall
Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall suspension
is measured from
ceiling to bottom
of luminaire
Finish
C041 White white
(low gloss)
C100 Satin anodized
finish
C099 Custom finish
Options
ACG
Adjustable cable grippers
BLK
Black cord, cord manager and canopy (not available
with F3 mtg)
CP
Chicago plenum (available with F1A only)
DL
Damp location label
DU
Dust cover
ELH
Emergency through wiring w/separate feed
ELS
Emergency through wiring w/single feed, shared neutral
ELS2
Emergency through wiring w/single feed, separate
neutrals
GLR
Fusing (fast blow)
GMF
Fusing (slow blow)
MCS
Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
OJB
Offset junction box
SLP
Sloped ceiling (for 10-45°, must be specified along with
F2, ACG and OJB options)
XXXX Integrated sensor; choose options and obtain code on
page 2
Notes:
1 Not available in 347V
2 Emergency type is installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified