Electric drive motor selection, Chapter 5 electric drive motor selection – Grain Systems Unload Augers PNEG-1555 User Manual
Page 25
PNEG-1555 8" Commercial Vertical Drive Unit - Dual Drive
25
5. Electric Drive Motor Selection
1. Knowing the bin size and the length of horizontal flight being used will be necessary to determine
how many horsepower is required for the job.
2. Use the following tables to determine the size of motor required. Use a larger motor when
encountering high moisture or when high capacity is required.
(See Tables 8" Flights and Motors
and Belt Selection on Page 26.)
3. The following horsepower recommendations are for moving fairly dry grain. Use an electric motor
of the proper size that operates at 1750 RPM. Motor pulleys are not furnished with the auger.
(See Tables 8" Flights and Motors below
and Belt Selection on Page 26.)
8" Flights and Motors
Product #
Part #
Description
Bin
Diameter
Unloader HP
Horizontal
Vertical
GFC82400
GK1799
14'-6" x 7" O.D. Flight
24'
3
5
GFC82700
GK1800
16'-0" x 7" O.D. Flight
27'
GFC83000
GK1801
17'-6" x 7" O.D. Flight
30'
5
GFC83300
GK1802
19'-6" x 7" O.D. Flight
33'-34'
GFC83600
GK1803
20'-6" x 7" O.D. Flight
36'
GFC83800
GK1804
22'-6" x 7" O.D. Flight
37'-39'
GFC84000
GK1805
23'-0" x 7" O.D. Flight
40'
GFC84200
GK1806
24'-0" x 7" O.D. Flight
42'
GFC84800
GK1807
7'-0" x 7" O.D. Flight (Intake)
48'-49'
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC85400
GK5878
10'-0" x 7" O.D. Flight (Intake)
54'-55'
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC86000
GK1810
13'-0" x 7" O.D. Flight (Intake)
60'
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC86300
GK5880
14'-6" x 7" O.D. Flight (Intake)
63'
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC86800
GK5881
17'-6" x 7" O.D. Flight (Intake)
68'-69'
7-1/2
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC87200
GK5882
19'-0" x 7" O.D. Flight (Intake)
72'
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC87500
GK5883
20'-6" x 7" O.D. Flight (Intake)
75'
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC87800
GK5884
22'-6" x 7" O.D. Flight (Intake)
78'
10
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC88000
GK5885
4'-6" x 7" O.D. Flight (Intake)
80'
GK1130
20'-0" x 7" O.D. Flight (Intermediate)
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC88200
GK5886
5'-6" x 7" O.D. Flight (Intake)
82'
GK1130
20'-0" x 7" O.D. Flight (Intermediate)
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC89000
GK5887
9'-6" x 7" O.D. Flight (Intake)
90'
GK1130
20'-0" x 7" O.D. Flight (Intermediate)
GK1808
20'-0" x 7" O.D. Flight (Discharge)
GFC89200
GK5888
10'-6" x 7" O.D. Flight (Intake)
92'
GK1130
20'-0" x 7" O.D. Flight (Intermediate)
GK1808
20'-0" x 7" O.D. Flight (Discharge)
A qualified electrician should install electrical controls and wiring. The motor
disconnect switches and conductor cables should comply with the National
Electrical code and any local codes which apply. Reset and motor starting
stations should be located so that the operator can see that all personnel are
clear of the equipment.