beautypg.com

Grain Systems Unload Augers PNEG-1555 User Manual

Page 14

background image

14 PNEG-1555 8" Commercial Vertical Drive Unit - Dual Drive

4. Installation

H. Remove the horizontal head plate from the vertical auger by removing the eight (8) 5/16'' x 1''

hex bolts, flat washers, lock washers and hex nuts.

Figure 4D

I. Unbolt and remove the 1-1/4'' four (4) hole flange bearing. Where possible, this bearing will be

reused with the new horizontal drive parts.

Figure 4E