4. Installation

PNEG-1555 8" Commercial Vertical Drive Unit - Dual Drive

17

C. Bolt the head plate assembly to the angle ring on the horizontal tube using four (4) 5/16" x 1"

bolts and serrated flange nuts. Use every other hole to attach the assembly to the tube.

NOTE: Where the first bolt and nut is placed in the head plate and angle ring is irrelevant. It is

important to use every other mounting hole in the head plate and angle ring.

Figure 4J

4. Assemble the bearing to the bearing plate.

A. Using the previously removed 1-1/4" flange bearing, bolt it to the bearing plate using

four (4) 1/2" x 1-1/2" bolts, lock washers, and hex nuts.

Figure 4K