Banks Power Ford Trucks: (Diesel ’08 - 10 6.4L Power Stroke) Tuner- Six-Gun Diesel Tuner & SpeedBrake, For use with Banks iQ '08-10 Compatible with PowerPDA User Manual
Page 30

30
96827 v.6.0
Table 1: Banks Six-Gun Fault Codes (Continued)
Code
Event
Course of Action
3,1
Engine Position
Sensor Fault.
Turn ignition OFF and check the 96-pin male and female PcM
connectors. Turn ignition back ON and re-check for presence
of code. If code does not re-appear at key ON, start engine
and check for presence of code both at engine idle and under
varying driving conditions.
3,2
Internal Module
Malfunction or
Intermittent Power.
Turn ignition OFF and check the 96-pin male and female PcM
connectors. Turn ignition back ON and re-check for presence
of code. If code does not re-appear at key ON, start engine
and check for presence of code both at engine idle and under
varying driving conditions.
3,3
EGR Valve Position
(EGRP) Input
Voltage Out of
Range.
Turn ignition OFF and check the 96-pin male and female PcM
connectors. Turn ignition back ON and re-check for presence
of code. If code does not re-appear at key ON, start engine
and check for presence of code both at engine idle and under
varying driving conditions.
3,4
OBDII cAN
communication
error
Turn ignition OFF and check the 4-pin male and female turbo
actuator connectors. Turn ignition back ON and re-check for
presence of code. If code does not re-appear at key ON, start
engine and check for presence of code both at engine idle and
under varying driving conditions.
4,1
EGR Valve Position
(EGRP) Output
Voltage Out of
Range.
Turn ignition OFF and check the 96-pin male and female PcM
connectors. Turn ignition back ON and re-check for presence
of code. If code does not re-appear at key ON, start engine
and check for presence of code both at engine idle and under
varying driving conditions.
4,2
Transmission
Slippage Detected.
Transmission is slipping excessively. Code will automatically
clear once transmission stops slipping (repaired).
4,3
Internal Module
Malfunction or
Intermittent Power.
Turn ignition OFF and check the 96-pin male and female PcM
connectors. Turn ignition back ON and re-check for presence
of code. If code does not re-appear at key ON, start engine
and check for presence of code both at engine idle and under
varying driving conditions.
4,4
Internal Memory
Malfunction.
Turn ignition OFF. Turn ignition back ON and re-check for
presence of code. If code does not re-appear at key ON, start
engine and check for presence of code both at engine idle and
under varying driving conditions.
If code/problem persists, note conditions when code appears and call Gale Banks Engineering Tech
Support.