beautypg.com

Tgt series, Specifications – Toner Cable TGT4 4 Port 1 GHz Taps User Manual

Page 2

background image

969 Horsham Road

l

Horsham, Pennsylvania 19044 USA

l

Phone: 215-675-2053 Fax: 215-675-7543

l

[email protected]

Specifications Subject To Change Without Notice

Rev

06-13

©Toner Cable Equipment, Inc.

TGT Series

2, 4, 8 & 12 Port 1 GHz Tap

S

pecifications

Return Loss

5-15 MHz

15-40 MHz

40-550 MHz

550-1000 MHz

Input

≥23 dB

≥25 dB

≥20 dB

≥20 dB

Output

≥25 dB

≥25 dB

≥22 dB

≥20 dB

Tap

≥25 dB

≥28 dB

≥20 dB

≥20 dB

Isolation

Port to Port

≥32 dB

≥35 dB

≥27 dB

≥27 dB

Tap to Output

≥40 dB

≥40 dB

≥27 dB

≥26 dB

Tap Value

Maximum Insertion Loss (dB) at frequency

Model

–1.0 dB

5-15 MHz

15-40 MHz

40-550 MHz

550-1000 MHz

2 PORT

TGT2-4T

4.0 dB

Terminating Tap

TGT2-8

8.5 dB

3.6

3.6

3.6

4.2

TGT2-11

11.0 dB

2.5

2.5

2.6

3.0

TGT2-14

14.5 dB

1.4

1.4

1.4

2.4

TGT2-17

17.0 dB

1.0

1.0

1.0

1.6

TGT2-20

20.0 dB

0.8

0.8

0.8

1.4

TGT2-23

23.0 dB

0.8

0.8

0.8

1.3

TGT2-26

26.0 dB

0.8

0.8

0.8

1.3

TGT2-29

29.0 dB

0.8

0.8

0.8

1.3

TGT2-32

32.0 dB

0.8

0.8

0.8

1.3

4 PORT

TGT4-8T

8.5 dB

Terminating Tap

TGT4-11

11.0 dB

3.6

3.6

3.8

4.4

TGT4-14

14.5 dB

2.5

2.3

2.6

3.0

TGT4-17

17.0 dB

1.4

1.4

1.4

2.4

TGT4-20

20.0 dB

1.0

1.0

1.0

1.6

TGT4-23

23.0 dB

0.8

0.8

0.8

1.4

TGT4-26

26.0 dB

0.8

0.8

0.8

1.3

TGT4-29

29.0 dB

0.8

0.8

0.8

1.3

TGT4-32

32.0 dB

0.8

0.8

0.8

1.3

8 PORT

TGT8-11T

11.0 dB

Terminating Tap

TGT8-14

14.5 dB

3.6

3.6

3.8

4.4

TGT8-17

17.0 dB

2.5

2.3

2.6

3.0

TGT8-20

20.0 dB

1.4

1.4

1.4

2.4

TGT8-23

23.0 dB

1.0

1.0

1.0

1.6

TGT8-26

26.0 dB

0.8

0.8

0.8

1.4

TGT8-29

29.0 dB

0.8

0.8

0.8

1.3

TGT8-32

32.0 dB

0.8

0.8

0.8

1.3

12 PORT (– 2 dB)

TGT12-17

17.5 dB

2.6

2.6

3.0

3.5

TGT12-20

20.0 dB

2.0

2.0

2.3

2.5

TGT12-23

22.5 dB

1.4

1.4

1.7

2.3

TGT12-26

26.0 dB

1.0

1.0

1.3

1.6

TGT12-29

29.0 dB

0.7

0.7

0.9

1.5