beautypg.com

Velleman CU2200 User Manual

Page 10

background image

CU2200

v

3-02

26.10.2012

©

Velleman nv

10

Operating Voltage Low Level Alarm Message

When the power supply voltage level is below the minimum level at 5.34VDC, the CU2200 will send

an alarm SMS message.

Date 2007-06-15
Time 13:25
ST:001;TM200706121325;V:5.34#

Operating Voltage Low Level Alarm

This command is used to set the action to be taken once the operating voltage drops below 7.0VDC.

Value of the current operating voltage can be retrieved by command 2.
Command: PWD:XXXX,ADCOUT0:YY,ZZZZBBBB,NNN%

XXXX Password
YY

00 means alarm not reported to control centre

10 means alarm reported to control centre 1

01 means alarm reported to control centre 2

11 means alarm reported to control centre 1 and 2

ZZZZBBBB

Selection of the alarm phone dial and alarm SMS

0 means no alarm report
1 means SMS only

2 means phone dial only => (Phone dial not available)

3 means SMS first, then phone dial =>(Phone dial not available)

Z Z Z Z

1

st

2

nd

3

rd

4

th

phone number

B B B B

5

th

6

th

7

th

8

th

phone number

NNN

Relay output control

0 means no relay output control
1 means relay output triggered by alarm

N N N

1

st

2

nd

3

rd

relay output

(2

nd

and 3

rd

relay output not available)

Arm/Disarm Setup

Command: PWD:XXXX,ARM%

XXXX Password

Example:

PWD:1234,ARM%

Password 1234
Unit is armed and in alert status

Command: PWD:XXXX,DISARM%

XXXX Password

Example:

PWD:1234,DISARM%

Password 1234
Unit is disarmed and no alarm is reported

c.

System Information Report

Default Setting

Command: PWD:1234,PARAMETER1%

ST:000;T:2006/10/01/01:01;H:1;F1:,00;F2;,00;XH:31#

Command: PWD:1234,PARAMETER2%

ST:000;VL:7.00,O:00,0000,000;A1M:5.000,0.000,1.000,0,5.000,0.500,O:00,00000000,000;A2M:
5.000,0.000,1.000,0,5.000,0.000,O:00,00000000,000#

Command: PWD:1234,PARAMETER3%

ST:000;K1:1,O:00,00000000,000;K2:1,O:00,00000000,000;K3:1,O:00,00000000,000;K4:1,O:00,

00000000,000;K5:1,O:00,00000000,000;K6:1,O:00,00000000,000;K7:1,O:00,00000000,000;K8:
1,O:00,00000000,000#

Command: PWD:1234,PARAMETER4%

ST:000;C1:,1;C2:,1;C3:,1;C4:,1;C5:,1;C6:,1;C7:,1;C8:,1;#

System Parameters RESET

Command: PWD:XXXX,PARAMETER&%

[SMS message received]

Parameter initialize success!