E M C P 3 . 2
G E N E R A T O R S E T C O N T R O L L E R

LEHE4942-02

2

Set points & software are stored in nonvolatile
memory, preventing loss during a power outage.

Compatibility with both mechanical and
electronic engines makes it versatile.

True RMS sensing ensures AC metering accuracy
to within ± 1% of rated AC voltage (L-L and L-N)
and current.

kW and kVA metering to within ± 5% of rating.

Three levels of security allow for configurable
operator privileges.

Single, standard 70-pin connector

COMMUNICATION

J1939 (Primary Data Link)

J1939 #2 (Accessory Data Link)

MODBUS RTU (1/2 duplex); RS-485
(Customer Communication)

ENVIRONMENTAL SPECIFICATIONS

Environmentally sealed front face rated for
IP56. Resistant to chemical splash, including:
diesel fuel, engine oil and machine oil.

Protection level IP22 for rear of controller

Resistant to salt spray

Vibration: withstands 4.3G @ 24-1000 Hz

Shock: withstands 15G

Monitoring Functionality & Controls
Operational from –40° C to 70° C
(–40° F to 158° F)

Display Operational from –20° C to 70° C
(–4° F to 158° F)

Storable from –40° C to 85° C (–40° F to 185° F)

0 to 95% Humidity, non-condensing from 30° C
to 60° C (86° F to 140° F)

STANDARDS

UL Recognized

CSA C22.2 No.100,14, 94

Complies with all necessary standards for
CE Certification
98/37/EC Machinery Directive

– BS EN 60204-1 Safety of Machinery

89/336/EEC EMC Directive

– BS EN 50081-1 Emissions Standard
– BS EN 50082-2 Immunity Standard

73/23/EEC Low Voltage Directive

– EN 50178 LVD Standard

ISO3046, ISO8528

IEC529, IEC60034-5, IEC61131-3

MIL STND 461

CONTROLS

Auto/Start/Stop

Engine Cool-Down timer

Emergency Stop

Engine Cycle Cranking

Lamp Test

Generator Voltage

Engine Speed/Generator Frequency

DIGITAL (LCD) INDICATION

Generator AC Voltage – 3 phase (L-L & L-N)

Generator AC Current (per phase & average)

Generator Power kW (total & per phase)

Generator kVAR (total & per phase)

Generator kVAR-hr (total)

Generator % of rated power (total)
(kW, kVA, kVAR)

Generator kVA (total & per phase)

Generator kW-hr (total)

Generator Power Factor (PF)
(average & per phase)

Generator Frequency

Engine RPM

Battery Voltage

Engine Hours

Engine Successful Start Counter

Engine Oil Pressure

Engine Coolant Temperature

Engine Crank Attempt Counter

Service Maintenance Interval
(Engine Operating Hours or Calendar Days)

Real Time Clock

Twenty (20) Event Fault Log

Notes:
1. Temperature indications are viewable in either

°C or °F (operator selectable)

2. Pressure indications are viewable in psi, kPa,

or bar

3. Fuel Consumption viewable in US/Imperial

gal/hr or Liters/hr

FEATURES/BENEFITS (CONT’D)

STANDARD FEATURES