Rectifier Diode, 40 A

Fig. 8 - Recovery Time Characteristics, T

J

= 25 °C

Fig. 9 - Recovery Time Characteristics, T

J

= 150 °C

Fig. 10 - Recovery Charge Characteristics, T

J

= 25 °C

Fig. 11 - Recovery Charge Characteristics, T

J

= 150 °C

Fig. 12 - Recovery Current Characteristics, T

J

= 25 °C

Fig. 13 - Recovery Current Characteristics, T

J

= 150 °C

225

25

0

40

120

200

t

rr

- Maxim

um Re

ver

se

Reco

ver

y

Time

(µs)

dI/dt - Rate of Fall of Forward Current (A/µs)

125

75

200

160

150

100

50

175

80

40EPF.. Series
T

J

= 25 °C

I

FM

= 80 A

I

FM

= 40 A

I

FM

= 20 A

I

FM

= 10 A

I

FM

= 5 A

I

FM

= 1 A

0

0

80

120

160

200

t

rr

- Maxim

um Re

ver

se

Reco

ver

y

Time

(µs)

dI/dt - Rate of Fall of Forward Current (A/µs)

0.4

0.6

0.2

0.8

40EPF.. Series
T

J

= 150 °C

40

I

FM

= 80 A

I

FM

= 5 A

I

FM

= 40 A

I

FM

= 20 A

I

FM

= 10 A

I

FM

= 1 A

0

0

80

120

200

Q

rr

- Maxim

u

m Re

ver

se

Reco

v

er

y Char

g

e

(µC)

dI/dt - Rate of Fall of Forward Current (A/µs)

3

1

2

4

160

40EPF.. Series
T

J

= 25 °C

I

FM

= 80 A

I

FM

= 20 A

I

FM

= 10 A

I

FM

= 5 A

I

FM

= 1 A

40

I

FM

= 40 A

0

0

80

120

160

200

Q

rr

- Maxim

u

m Re

ver

se

Reco

ver

y

Char

g

e

(µC)

dI/dt - Rate of Fall of Forward Current (A/µs)

2

4

6

8

10

40EPF.. Series
T

J

= 150 °C

I

FM

= 80 A

I

FM

= 20 A

I

FM

= 10 A

I

FM

= 5 A

I

FM

= 1 A

40

I

FM

= 40 A

25

0

0

80

120

160

200

I

rr

- Maxim

u

m Re

ver

se

Reco

ver

y

Current (A)

dI/dt - Rate of Fall of Forward Current (A/µs)

10

20

5

15

40EPF.. Series
T

J

= 25 °C

I

FM

= 80 A

I

FM

= 20 A

I

FM

= 10 A

I

FM

= 5 A

I

FM

= 1 A

40

I

FM

= 40 A

50

20

0

0

40

120

160

200

I

rr

- Maxim

u

m Re

ver

se

Reco

ver

y

Current (A)

dI/dt - Rate of Fall of Forward Current (A/µs)

40

10

30

40EPF.. Series
T

J

= 150 °C

80

I

FM

= 80 A

I

FM

= 40 A

I

FM

= 20 A

I

FM

= 10 A

I

FM

= 5 A

I

FM