Vishay 30CPF..PbF Soft Recovery Series User Manual
Vishay high power products, Rohs
Document Number: 94101
For technical questions, contact: [email protected]
www.vishay.com
Revision: 08-Jul-08
1
Fast Soft Recovery
Rectifier Diode, 30 A
30EPF..PbF, 30CPF..PbF Soft Recovery Series
Vishay High Power Products
FEATURES/DESCRIPTION
The 30EPF..PbF and 30CPF..PbF soft recovery
rectifier series has been optimized for combined
short reverse recovery time and low forward
voltage drop.
The glass passivation ensures stable reliable operation in
the most severe temperature and power cycling conditions.
30CPF series is a drop in replacement for 25CPF series
(parallel connection only).
This product series has been designed and qualified for
industrial level and lead (Pb)-free.
APPLICATIONS
• Output rectification and freewheeling in inverters,
choppers and converters
• Input rectifications where severe restrictions on conducted
EMI should be met
PRODUCT SUMMARY
V
F
at 30 A
< 1.41 V
t
rr
95 ns
V
RRM
1000 to 1200 V
30CPF..
30EPF..
2
1
3
Cathode
Anode
TO-247AC modified
2, 4
Anode
1
Anode
3
TO-247AC
Base
common
cathode
Base
common
cathode
Available
Pb-free
RoHS*
COMPLIANT
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL
CHARACTERISTICS
VALUES
UNITS
I
F(AV)
Sinusoidal waveform
30
A
V
RRM
1000 to 1200
V
I
FSM
350
A
V
F
30 A, T
J
= 25 °C
1.41
V
t
rr
1 A, 100 A/µs
95
ns
T
J
- 40 to 150
°C
VOLTAGE RATINGS
PART NUMBER
V
RRM
, MAXIMUM PEAK
REVERSE VOLTAGE
V
V
RSM
, MAXIMUM NON-REPETITIVE
PEAK REVERSE VOLTAGE
V
I
RRM
AT 150 °C
mA
30EPF10PbF, 30CPF10PbF
1000
1100
6
30EPF12PbF, 30CPF12PbF
1200
1300
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
Maximum average forward current
I
F(AV)
T
C
= 95 °C, 180° conduction half sine wave
30
A
Maximum peak one cycle
non-repetitive surge current
I
FSM
10 ms sine pulse, rated V
RRM
applied
300
10 ms sine pulse, no voltage reapplied
350
Maximum I
2
t for fusing
I
2
t
10 ms sine pulse, rated V
RRM
applied
450
A
2
s
10 ms sine pulse, no voltage reapplied
636
Maximum I
2
√t for fusing
I
2
√t
t = 0.1 to 10 ms, no voltage reapplied
6360
A
2
√s
* Pb containing terminations are not RoHS compliant, exemptions may apply