beautypg.com

Altronix ALTV244ULCB3 Installation Instructions User Manual

Page 2

background image

Overview:

The following Altronix CCTV Power Supplies provide 24VAC or 28VAC distributed via four (4) fuse or PTC protected
outputs for powering CCTV Cameras, heaters and other video accessories.

Four (4) Output ALTV244UL Reference Chart:

ALTV244UL

24VAC 3.5 amp

4

--

Yes

3.5

3.5

5 amp/ 3.5 amp/

.9

28VAC

3 amp

amp

amp

250V

250V

amp

ALTV244ULX

24VAC 3.5 amp

4

--

Yes

3.5

3.5

5 amp/ 3.5 amp/

.9

28VAC

3 amp

amp

amp

250V

250V

amp

ALTV244ULCB

24VAC 3.5

amp

4

Yes

--

2.5

--

5 amp/ 3.5 amp/

.9

28VAC

3 amp

--

Yes

amp

250V

250V

amp

ALTV244175UL

24VAC 7

amp

4

--

Yes

3.5

3.5

10 amp/

--

2.7

28VAC 6.25 amp

amp

amp

250V

amp

ALTV244175ULCB

24VAC 7

amp

4

Yes

--

2.5

--

10 amp/

--

2.7

28VAC 6.25 amp

amp

250V

amp

Specifications:

Installation Instructions:

1. Mount unit in desired location.
2. Set power switch on power distribution board marked [PD] to OFF position for models ALTV244UL, ALTV244ULX

or ALTV244ULCB (Figs. 1-3, pgs. 4, 5). Set power disconnect circuit breaker to OFF position for models
ALTV244175UL or ALTV244175ULCB (Figs. 4a, 5a, pg. 6).

- 2 -

Altronix
Model Number

In

di

vi

du

al

O

ut

pu

t C

ur

re

nt

(m

ax

pe

r

ou

tp

ut

no

t t

o

ex

ce

ed

to

ta

l o

ut

pu

t c

ur

re

nt

)

To

ta

l O

ut

pu

t C

ur

re

nt

(P

ow

er

)

O

ut

pu

t V

ol

ta

ge

11

5V

A

C

50

/6

0H

z

In

pu

t C

ur

re

nt

Fu

se

Pr

ot

ec

te

d

C

la

ss

1

O

ut

pu

ts

N

um

be

r

of

O

ut

pu

ts

Pr

im

ar

y

In

-l

in

e

Fu

se

R

at

in

gs

• UL Listed for Commercial CCTV Equipment (UL 2044).

CUL Listed - CSA Standard C22.2 No.1-98,
Audio, Video and Similar Equipment.

• Surge suppression.
• AC power LED indicator.
• Power ON/OFF switch (ALTV244UL, ALTV244ULX

or ALTV244ULCB).

• Illuminated power disconnect circuit breaker

with manual reset (ALTV244175UL,
ALTV244175ULCB).

• Unit maintains camera synchronization.
• Ease of installation saves time & eliminates costly labor.
• Spare fuses included (on fuse protected models).

Enclosure Dimensions:

ALTV244UL, ALTV244ULCB
8.5"H x 7.5"W x 3.5"D
ALTV244ULX
13"H x 13.5"W x 3.25"D
ALTV244175UL, ALTV24175ULCB
12.25"H x 7.75"W x 4.5"D

Fu

se

R

at

in

gs

M

ai

n

Fu

se

R

at

in

gs

A

ge

nc

y

L

is

tin

gs

PT

C

Pr

ot

ec

te

d

O

ut

pu

ts

(C

la

ss

2

po

w

er

lim

ite

d

fo

r

D

ry

lo

ca

tio

ns

).

(C

la

ss

3

fo

r W

et

lo

ca

tio

ns

).