- 8 -

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)

Power Supply Board Stand-by Battery Specifications:

Altronix

Model

Power Supply

Board

Battery

20 Min. of Backup

4 Hr. of Backup

24 Hr. of Backup

Maximal11D

AL400ULXB2

(Refer to Fig. 1a, pg. 9

for Switch [SW1]

location and position)

12VDC/40AH*

N/A

3.5 amp

0.5 amp

24VDC/40AH*

N/A

2.7 amp

0.7 amp

Maximal33D

AL600ULXB

(Refer to Fig. 1a, pg. 9

for Switch [SW1]

location and position)

12VDC/40AH*

N/A

5.5 amp

5.5 amp

24VDC/40AH*

N/A

5.5 amp

0.7 amp

Maximal55D

Maximal75D

AL1012ULXB

(Factory set at 12VDC)

12VDC/12AH

9.0 amp

Battery capacity for

emergency stand-by

at least 20 mins.

N/A

Maximal75D

AL1024ULXB

(Factory set at 24VDC)

24VDC/12AH

7.7 amp

1.2 amp

N/A

Maximal77D

AL1024ULXB

(Factory set at 24VDC)

24VDC/65AH*

N/A

7.7 amp

1.2 amp