Altronix eBridge1PCRMT Installation Instructions User Manual
Page 2

- 2 -
eBridge1PCRMT
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
eBridge1PCTX and eBridge1PCRM are not intended to be connected to outside plant leads and should be installed
indoors within the protected premises. eBridge1PCTX and eBridge1PCRM are intended for indoor use only.
1.
eBridge1PCRM installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s mounting hole
(Fig. 2a, pg. 3). Unit should be mounted in proximity to ethernet switch/network, NVR or video server.
b.
Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked [10/100BaseT]
(Fig. 2, pg. 3).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
d. A local AUX input 24VAC or 24VDC can be used to power the eBridge1PCRM. This will eliminate the
need for the eBridge1PCRM to draw power from the midspan/endspan thus making the midspan/endspan additional
power available to the end PoE powered device.
2.
eBridge1PCTX installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole
(Fig. 2a, pg. 3). Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 3).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
Note: The eBridge1PCRMT is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is
important to note that some high resolution and high frame rate cameras may demand faster headend processing ability,
such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the
image may show pixilation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolu-
tion may be reduced to accommodate system equipment.
Technical Specifications:
Parameter
Description
Connections
BNC for Coax link. RJ45 for ethernet link.
Input power
requirements
Midspan or endspan port connected. AUX input for powering.
Indicators
Blue: Coax Link.
Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.
Green: Power.
Environmental
Conditions
Operating Ambient Temperature: UL60950-1
eBridge1PCRM: -- 4ºF to 140ºF (-- 20ºC to +60ºC).
eBridge1PCTX: -- 4ºF to 140ºF (- 20ºC to +60ºC).
Relative humidity: 85%, +/ --- 5%
Storage Temperature: -- 4º to 158ºF (--- 20º to 70ºC) Storage
Operating Altitude: -- 1000 to 6,561.679 ft. (-- 304.8 to 2000m).
Regulatory
Compliance
UL/CUL Listed for Information Technology Equipment (UL 60950-1).
CE approved. C-Tick compliant.
Weights (approx.) Product: 5.1 oz. (0.144 kg.), Shipping: 7.76 oz. (0.22 kg.)
Fig. 1
eBridge1PCRM
eBridge1PCTX
Green LED
indicates
Power
Structured
Cable from
midspan/endspan
Structured
Cable from
IP Camera/Device
Blue LED
indicates
Coax Connection
Blue LED
indicates
Coax Connection
Green LED
indicates
Power
Yellow LED
indicates PoE
Coax
Cable from
eBridge1PCT or
eBridge1PCTX
Aux.
24VAC or
24VDC
Input
Coax
Cable from
eBridge1PCRM