4
Technical Data
4.1
Physical Features
Danger!
Overvoltage.
Fire hazard!
The MoRoS Modem - ISDN 1.3 must be secured with a
suitable fuse against overvoltage.
All specified data was measured with a nominal input voltage, at full load, and an ambi-
ent temperature of 25 °C. The threshold value tolerances are subject to typical fluctua-
tions.
Physical Feature
Value
Operating voltage
10..60V DC voltage
Power input sleep
2W
Power input connection
3W
Level inputs
Level HIGH = 4-12V
Level LOW = 0-1V
Current consumption of an active input
against GND (internal +5V)
Typically 0.35mA
Switch output, maximum switch voltage
30V (DC) / 42V (AC)
Switch output, maximum current load
1 A (DC) / 0.5 A (AC)
Weight
10.58oz
Dimensions (Width x Depth x Height)
70mm x 110mm x 75mm
Temperature range
0°C – 55°C
Maximum allowed humidity
95% non-condensing
Protection class
Housing IP40, Terminals IP20
Table 1: Physical Features