VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire, approval according to LPR radio standard User Manual
Page 71
Tracking speed of the measuring window
max.
1 m/min
Beam angle
3)
-
Horn antenna ø 75 mm (2.953 in)
10°
-
Horn antenna ø 95 mm (3.74 in)
8°
Emitted HF power
4)
-
Average spectral transmission power
density
-34 dBm/MHz EIRP
-
Max. spectral transmission power den-
sity
+
6 dBm/50 MHz EIRP
-
Max. power density in a distance of 1 m
<
1 µW/cm²
Ambient conditions
Ambient, storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
For the process conditions, please also note the specifications on the type label. The lowest value
always applies.
Seal
Antenna impedance co-
ne
Process temperature (measured on the process
fitting)
FKM (SHS FPM 70C3
GLT)
PTFE
-40 … +130 °C (-40 … +266 °F)
PTFE
5)
-40 … +200 °C (-40 … +392 °F)
PEEK
6)
-40 … +200 °C (-40 … +392 °F)
FFKM (Kalrez 6375)
PTFE
-20 … +130 °C (-4 … +266 °F)
PEEK
-20 … +250 °C (-4 … +482 °F)
FFKM (Kalrez 2035)
PTFE
-15 … +130 °C (5 … +266 °F)
PEEK
-15 … +210 °C (5 … +410 °F)
FFKM (Kalrez 6230)
PTFE
-15 … +130 °C (5 … +266 °F)
PEEK
-15 … +250 °C (5 … +482 °F)
Graphite
Ceramic
-200 … +450 °C (-328 … +842 °F)
Vessel pressure - horn antenna
-
Antenna impedance cone PTFE
-1 … 40 bar (-100 … 4000 kPa/-14.5 … 580 psig)
-
Antenna impedance cone PP
-1 … 3 bar (-100 … 300 kPa/-14.5 … 43.5 psig)
3)
Outside the specified beam angle, the energy of the radar signal has a level
which is reduced by 50 % (-3 dB)
4)
EIRP: Equivalent Isotropic Radiated Power
5)
Not with steam
6)
Not with steam
VEGAPULS
62 • 4 … 20 mA/HART - two-wire, approval according to LPR radio standard
71
11 Supplement
41718
-EN
-120301