6 Setup with the integrated display and adjustment unit
PLICSRADIO C62 • Wireless processing unit for PLICSRADIO T62
32627-EN-130701
→
Enter the requested parameters via the appropriate keys and
save your settings with [OK].
The relay and current outputs are arranged under "Outputs". Meas-
ured loops 4 … 6 (switching inputs) are fix assigned to relays 1 … 3.
In case of failure you can determine if the switching status of the relay
remains unchanged or the relay is switched off.
Measurement loops 1 … 3 (continuous inputs) are fix assigned to cur-
rent outputs 1 … 3. In case of failure you can determine which value
the current output should accept.
→
Enter the requested parameters via the appropriate keys and
save your settings with [OK].
In the menu item "Display - Indication value", you can set the re-
quested indication value. The following options are available:
•
Percent: adjusted measured value without taking a probably
stored linearization into account
•
Lin. percent: adjusted measured value by taking a probably
stored linearization into account
•
Scaled: adjusted measured value by taking a probably stored
linarization into account as well as the values entered under "Scal-
ing"
•
Sensor value: input value delivered by the sensor. Presentation in
the selected adjustment unit
→
Enter the requested parameters via the appropriate keys and
save your settings with [OK].
When the instrument displays a failure message, further information is
available under the menu item "Diagnosis - Device status".
Meas. loop - Outputs -
Relays outputs
Meas. loop - Outputs -
Current outputs
Display
Diagnostics