VEGA VEGABAR 64 Profibus PA User Manual
Page 60
Adjustment elements
4 keys
Protection class
-
unassembled
IP
20
-
mounted into the sensor without cover
IP
40
Materials
-
Housing
ABS
-
Inspection window
Polyester foil
Power supply
Operating voltage
-
Non-Ex instrument
9 … 32 V DC
-
EEx-ia instrument
9 … 24 V DC
-
EEx-id instrument
9 … 32 V DC
Operating voltage with lighted indicating and adjustment module
17)
-
Non-Ex instrument
12 … 36 V DC
-
EEx-ia instrument
12 … 30 V DC
-
EEx-id instrument
12 … 32 V DC
Power supply by/max. number of sensors
-
DP/PA segment coupler
max. 32 (max. 10 with Ex)
-
VEGALOG
571 EP card
max. 15 (max. 10 with Ex)
Electrical protective measures
Protection class
-
Housing, standard
IP
66/IP 67
18)
-
Aluminium and stainless housing (op-
tionally available)
IP
68 (1 bar)
19)
-
Transmitter in IP 68 version
IP
68
-
External housing
IP
65
Overvoltage category
III
Protection class
II
Approvals
Depending on the version, instruments with approvals can have different technical data.
17)
Is available at a later date for instruments with StEx, WHG or ship approval
as well as country-specific approvals such as those according to FM or
CSA.
18)
Instruments with gauge pressure measuring ranges cannot detect the am-
bient pressure when submerged, e.g. in water. This can lead to falsification
of the measured value.
19)
Only with instruments with absolute pressure ranges.
60
VEGABAR
64 • Profibus PA
10 Supplement
28252
-EN