10 supplement, 1 technical data – VEGA VEGABAR 64 Profibus PA User Manual
Page 52
10 Supplement
10.1 Technical data
General data
Parameter, pressure
Gauge pressure, absolute pressure, vacuum
Measuring principle
Ceramic-capacitive, dry measuring cell
Communication interface
I
²C bus
Materials and weights
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
-
Process fitting
316L, PVDF, PVDF plated, Hastelloy C4 plated
-
Diaphragm
sapphire ceramic
®
(99.9 % oxide ceramic)
-
Joining material diaphragm/Basic ele-
ment measuring cell
Glass solder
-
Measuring cell seal
FKM (VP2/A), FFKM (Kalrez 6375), EPDM (A+P
75.5/KW75F), FFKM (Chemraz 535), FFKM (FDA/
3A)
-
Seal, process fitting thread G1½ A
Klingersil C-4400
Materials, non-wetted parts
-
Electronics housing
Plastic PBT (polyester), Alu die-casting powder-
coated, 316L
-
External electronics housing
plastic PBT (Polyester)
-
Socket, wall mounting plate external
electronics housing
plastic PBT (Polyester)
-
Seal between housing socket and wall
mounting plate
TPE (fixed connected)
-
Seal, housing cover
NBR (stainless steel housing), silicone (Alu/plastic
housing)
-
Inspection window in housing cover for
indicating and adjustment module
Polycarbonate (UL-746-C listed)
-
Ground terminal
316Ti/316L
-
Connection between IP 68 transmitter
and external electronics housing
PUR, FEP, PE
-
Type plate support with IP 68 version on
cable
PE hard
Weight approx.
0.8 … 8 kg (1.764 … 17.64 lbs), depending on
process fitting
Output variable
Output signal
digital output signal, format according to IEEE-754
Sensor address
126 (default setting)
52
VEGABAR
64 • Profibus PA
10 Supplement
28252
-EN