beautypg.com

10 supplement, 1 technical data – VEGA VEGABAR 64 Profibus PA User Manual

Page 52

background image

10 Supplement

10.1 Technical data

General data

Parameter, pressure

Gauge pressure, absolute pressure, vacuum

Measuring principle

Ceramic-capacitive, dry measuring cell

Communication interface

I

²C bus

Materials and weights

Material 316L corresponds to 1.4404 or 1.4435

Materials, wetted parts

-

Process fitting

316L, PVDF, PVDF plated, Hastelloy C4 plated

-

Diaphragm

sapphire ceramic

®

(99.9 % oxide ceramic)

-

Joining material diaphragm/Basic ele-
ment measuring cell

Glass solder

-

Measuring cell seal

FKM (VP2/A), FFKM (Kalrez 6375), EPDM (A+P
75.5/KW75F), FFKM (Chemraz 535), FFKM (FDA/
3A)

-

Seal, process fitting thread G1½ A

Klingersil C-4400

Materials, non-wetted parts

-

Electronics housing

Plastic PBT (polyester), Alu die-casting powder-
coated, 316L

-

External electronics housing

plastic PBT (Polyester)

-

Socket, wall mounting plate external
electronics housing

plastic PBT (Polyester)

-

Seal between housing socket and wall
mounting plate

TPE (fixed connected)

-

Seal, housing cover

NBR (stainless steel housing), silicone (Alu/plastic
housing)

-

Inspection window in housing cover for
indicating and adjustment module

Polycarbonate (UL-746-C listed)

-

Ground terminal

316Ti/316L

-

Connection between IP 68 transmitter
and external electronics housing

PUR, FEP, PE

-

Type plate support with IP 68 version on
cable

PE hard

Weight approx.

0.8 … 8 kg (1.764 … 17.64 lbs), depending on
process fitting

Output variable

Output signal

digital output signal, format according to IEEE-754

Sensor address

126 (default setting)

52

VEGABAR

64 • Profibus PA

10 Supplement

28252

-EN

-081209