VEGA VEGAPULS 45 4 … 20 mA; HART compact sensor User Manual
Page 9
VEGAPULS 42, 44 and 45 – 4 … 20 mA
9
Types and versions
Survey
General features
• Application preferably for liquids in storage tanks and process vessels with increased
accuracy requirement.
• Measuring range 0 … 4 m, 0 … 10 m or 0 … 20 m.
• Ex approved in Zone 1 (IEC) or Zone 1 (ATEX) classification mark
EEx ia [ia] IIC T6.
• Integrated measured value display.
Survey
PS42XXD…
PS44XXD…
PS45XXXD…
Signal output
- active (4 … 20 mA)
•
•
•
- passive (4 … 20 mA, loop powered)
•
•
•
Antenna
- horn antenna
•
•
–
- pipe antenna
1)
1)
•
Process connection
- G 1½ A; 1½“ NPT
•
–
•
- DN 50; ANSI 2“
–
•
•
- DN 80; ANSI 3“
–
•
•
- DN 100; ANSI 4“
–
•
•
- DN 150; ANSI 6“
–
•
•
Adjustment
- P C
•
•
•
- adjustment module in the sensor
•
•
•
- adjustment module in external
indicating instrument
•
•
•
- HART
®
handheld
•
•
•
Measuring range
0 … 4 m
- ø 40 mm horn
0 … 10 m
–
(dependent on
- ø 48 mm horn
0 … 15 m
0 … 15 m
tube length)
- ø 75 mm horn
0 … 20 m
0 … 20 m
- ø 95 mm horn
0 … 20 m
0 … 20 m
1)
If the sensor is mounted on a standpipe or bypass tube, a pipe antenna is created. The tube inner diameter
should be between 40 mm and 80 mm.