Adjustment without medium

(adjustment independent of the level)

Key adjustment

Display indication

Adjust-
ment

Para-
meter

Sensor

m(d)

4.700

w.o
medium

Ad-
just-
ment
in

m(d)

(min. adjustment)

OK

OK

+

OK

OK

OK

Ad-
just-
ment
in

m(d)

0.0%

at

m (d)

XX.XXX

OK

+

or

The distance indication flashes
and you can choose "feet“ and
"m“.

Confirm the adjustment with
"

OK“.

With "

+“ and "–“ you adjust the

percentage value for the min.
value (example 0.0 %).

The entered percentage value
is written in the sensor and the
min. distance value corres-
ponding to that percentage
value flashes.

2. Operating range

Without special adjustment, the operating
range corresponds to the measuring range.
Generally, it is useful to choose a slightly
wider range (approx. 5 %) for the operating
range than for the measuring range.

Example:
Min./max. adjustment: 1.270 … 5.850 m;
adjust operating range to approx.
1.000 … 6.000 m.

3. Adjustment

Max.

Min.

100 % (1.270 m) correspond
to 1200 liters

Span (4.58 m)

0 % (5.850 m) corresponds
to 45 liters

Under the menu item "

Adjustment“ you inform

the sensor of the measuring range it should
operate in.

You can carry out the adjustment with or
without medium. Generally, you will carry out
the adjustment without medium, as you can
then adjust without a filling/emptying cycle.

Set-up