beautypg.com

Adjustment with the hart, Handheld, Adjustment with the adjustment module minicom – VEGA VEGAPULS 56K User Manual

Page 8: Handheld into the ad- justment jacks on the sensor, Product description, Hart, Handheld hart, Handheld on the 4 … 20 ma signal cable

background image

8

VEGAPULS 56K

22915-EN-041227

HART

®

handheld

HART

®

handheld on the 4 … 20 mA signal cable

Adjustment with the HART

®

handheld

VEGAPULS series 50 sensors with
4 … 20 mA output signal can also be ad-
justed with the HART

®

handheld. A special

DDD (Data Device Description) is not neces-
sary - the sensors can be adjusted with the
HART

®

standard menus of the handheld.

To make adjustments, simply connect the

HART

®

handheld to the 4 … 20 mA output

signal cable or insert the two communication
cables of the HART

®

handheld into the ad-

justment jacks on the sensor.

2

2

4 ... 20 mA

HART Communicator

Product description

Adjustment with the adjustment module
MINICOM

With the small (3.2 cm x 6.7 cm) 6-key ad-
justment module with display, the adjustment
can be carried out in clear text dialogue. The
adjustment module can be plugged into the
radar sensor or into the optional, external
indicating instrument.

Unauthorised sensor adjustments can be
prevented by removing the adjustment mod-
ule.

Detachable adjustment module MINICOM

Adjustment with detachable adjustment module on the
radar sensor or on the external indicating instrument
VEGADIS 50

-

+

ESC

OK

2

4

Tank 1
m (d)
12.345

-

+

ESC

OK

Tank 1
m (d)
12.345

4 ... 20 mA

-

+

ESC

OK

Tank 1

m (d)
12.345