VEGAPULS 56K

45

22915-EN-041227

7 Technical data

7.1 Data

Power supply

Supply voltage
- two-wire sensor

24 V DC (20 … 36 V DC)

- four-wire sensor

24 V DC (20 … 72 V)
230 V AC (20 … 250 V), 50/60 Hz
fuse 0.5 A TR

Load diagram (loop resistance of e.g. PLC and supply cable)

Current consumption
- two-wire sensor

max. 22.5 mA

- four-wire sensor

max. 60 mA

Power consumption
- two-wire sensor

max. 80 mW,

0.45 VA

- four-wire sensor

max. 200 mW,

1.2 VA

Measuring range

1)

Standard

0 … 20 m

Measurement in a standpipe
- VEGAPULS 56 on DN 50

0 … 16 m

- VEGAPULS 56 on DN 100

0 … 19 m

Output signal (see also „Outputs and processing“)

4 … 20 mA current signal
Load
- four-wire sensor

max. 500

- two-wire sensor

see above diagram

Technical data

1000

V

680

500

250

0

20

22

24

26

28

30

32

34

36

19 V

Voltage limit
non-Ex sensor

Voltage limit
Ex sensor

HART

®

load

1)

Min. distance from the antenna top to the medium 5 cm