Product temperature, And operating pressure, Product description – VEGA Capacitive electrodes EL Profibus PA User Manual
Page 10
10
Capacitive electrodes EL - Profibus PA
3
2
1
EL 21 up to 16 bar
Temperature
adapter
EL 42:
up to 16 bar
EL 24:
from 100°C 6 bar,
max. 150°C for
30 min.
Product description
1)
For Ex applications, the permissible temperatures and pressures stated in the certificate must be noted.
Please observe the table on the following page.
0
-30
60
80
40
bar
˚C
16
0
-50
100
63
˚C
bar
0
-50
100
63
200 ˚C
bar
25
PE
PTFE
FEP
PE PA12
Product temperature
1)
and operating
pressure
1)
The numbers in the tables all relate to the
graphs on this page. The stated pressures
are valid for screw connections G
3
/
4
A,
3
/
4
" NPT, G 1 A, 1" NPT. When using flanged
versions, make sure to note their nominal
pressure. All electrodes are also suitable for
applications in a vacuum (-1 bar).
For electrodes certified for Ex zone 0, only
PTFE and FEP are approved as insulating
materials.
Mechanical connection, 1.4571
Insulation
Electrode type
EL 11
1
3
-
-
EL 21
1
3
-
-
EL 21 with flange
-
2
-
-
EL 24
-
-
2
-
EL 29
-
-
2
-
EL 31
1
3
-
-
EL 42
-
-
-
-
EL 52
-
3
-
-
EL 53
-
-
-
1
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)