VEGASON 54K … 56K

9

-

+

4 … 20 mA

2

2

2

4

3

200

Measuring system consisting of VEGASON 54K … 56K with any 4 … 20 mA
processing unit

• Four-wire technology, supply and output signal via two separate two-wire cables
• Output signal 4 … 20 mA active
• Optional external indicating instrument with analogue and digital indication (can be mounted

up to 25 m from the sensor)

• Adjustment with PC, HART

®

handheld or adjustment module MINICOM (pluggable in the

sensor or in the external VEGADIS 50 indicating instrument)

• Max. resistance on the signal output (load) 500

VEGADIS 50

1 )

1)

If the resistance of the processing systems con-
nected to the 4 … 20 mA signal output is less than
200

, a resistor must be connected to the con-

nection cable during adjustment, to reach an ad-
justment load of 200

to 350

.

The digital adjustment signal would otherwise be
extremely damped or short circuited because of in-
sufficient resistance of the connected processing
system. Communication with the PC would no
longer be ensured.

HART

®

handheld

VEGA-
CONNECT 2

2)

4 … 20 mA active means, that the sensor delivers
a level-dependent current of 4 … 20 mA (source).
With respect to the processing system (e.g. dis-
play), the sensor acts electrically as a current
source.

(active)

2)