Set-up - Adjustment with the adjustment module MINICOM
Fast
change
Yes
act.
dist.
m
X,XX
Light grey menu fields are only
displayed if required (dependent on
the adjustments in other menus).
Menu items in bolt print provide
sensor and measured value
information and cannot be modified
in this position.
High
dust
level
No
White menu items can be modified
with the "+“ or "–“ key and saved
with the "OK“ key.
Simulation:
Simulation:
Simulation:
Simulation:
Simulation:
One hour after the last simulation adjust-
ment, the sensor returns automatically to
normal operating mode.
Error codes:
E013
No valid measured value
-
Sensor in the warm-up phase
-
Loss of the useful echo
E017
Adjustment span too small
E036
Sensor program not operating
-
Sensor must be programmed
(service)
-
Fault signal also appears during
programming
E040
Hardware failure, electronics
defective
Create
new
Dis-
tance
m (d)
4.700
False
echo
memory
Meas.
dist.
OK
?
Meas.
dist.
m (d)
X.XX
learn-
ing
Update
Update
Now
!
OK
?
learn-
ing
Delete
delet-
ing
Delete
Now
!
OK
?
Add´l
func-
tions
Info
Lan-
guage
Eng-
lish
Reset
Now
!
OK
?
Reset-
ing
Basic
reset
Sensor
type
PULS54
K
Serial
number
1094
0213
Softw.
vers.
2.00
Dis-
tance
m (d)
4.700
max.
range
m (d)
7.000
Sensor
Tag
Sensor
Softw.
date
15.09.
1999
Meas.
dist.
m (d)
X.XX
Ampl.:
XX dB
S-N:
XX dB
Ampl.:
XX dB
S-N:
XX dB
6.
7.
Simu-
lation
Simu-
lation
Now!
OK
?
Simu-
lation
%
XXX.X
Cur-
rent
mA
8.565
Sensor
addr.
0
Tempe-
rature
Actual
temp.
18°C
Min.
temp.
4°C
Max.
temp.
59°C
With these keys you move in
the menu field to the left, right,
top and bottom
ESC
OK