3 technical data, 1 data – VEGA VEGASON 54K…56K User Manual
Page 12
12
VEGASON 54K … 56K
Technical data
3 Technical data
3.1 Data
Power supply
Power supply
230 V AC (20 … 253 V AC), 50/60 Hz
24 V DC (20 … 72 V DC)
fuse 0.315 A TR
Current consumption
max. 160 mA
Power consumption
max. 2 W, 3.5 VA
Measuring range
(the transducer end is the reference plane for sensor version B … D. The lower edge of the
flange is the reference plane for sensor version A)
VEGASON 54
1.0 … 25 m (solid: 1.0 … 15 m)
VEGASON 55
0.8 … 45 m
VEGASON 56
- version A
1.8 … 70 m
- version B … D
1.4 … 70 m
Output signal
Signal output
4 … 20 mA current signal in four-wire technology
Load
500
Ω
Integration time
0 … 999 seconds (adjustable)
Fault signal
current signal unchanged 20.5 mA, 22 mA
(adjustable)
Four-wire technology:
Separate power supply. The analogue 4 … 20 mA output signal (measuring signal) is car-
ried on a cable separate from the power supply.
Display module (optional)
Liquid crystal display
- in the sensor
scalable measured value output as graph and
numerical value
- powered externally by the sensor
scalable measured value output as graph and
numerical value. The display module can be
mounted up to 25 m away from the sensor.
Adjustment
- PC with adjustment software VEGA Visual Operating
- Adjustment module MINICOM
- HART
®
handheld