beautypg.com

7 incorrect mounting – VEGA VEGASON 54K…56K User Manual

Page 32

background image

32

VEGASON 54K … 56K

60 %

0 %

100 %

4.7 Incorrect mounting

Foam generation

Thick foam on the product can cause incor-
rect measurements. Take measures to avoid
foam, carry out the measurement in a bypass
tube, or use a different measuring technol-
ogy, e.g. capacitive measuring probes or
hydrostatic pressure transmitters.

Foam generation

Orient the sensor perpendicularly to the product
surface

Wrong orientation to the product

Weak measuring signals are the result if the
sensor is not directly pointed at the product
surface. Orient the sensor axis perpendicu-
larly to the product surface to achieve opti-
mum measuring results.

Strong turbulences

Strong product movements

Strong turbulences in the vessel, e.g. by
power ful stirrers or strong chemical reac-
tions, seriously interfere with the measure-
ment. A surge or bypass tube of sufficient
size (DN 200, DN 250) always allows, pro-
vided the product causes no buildup in the
tube, a reliable measurement even with
strong turbulence in the vessel.

Mounting and installation

Buildup

Correct

Wrong