beautypg.com

4 technical data and dimensions – VEGA VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex User Manual

Page 7

background image

VEGASWING 81 W5 Ex.C, 83 W5 Ex.C fail safe

7

Product description

1.4 Technical data and dimensions

VEGASWING 81 W5 Ex.C and 83 W5 Ex.C

Housing

Housing material

PBT (Polyester)

Protection

IP 66

Cable entry

1 x Pg 13,5

Terminals

max. 1 x 1,5 mm

2

Mechanical connection

Thread

G 1 A or 1“ NPT

- material

1.4571 (V4A) or Hastelloy C4 (2.4610)

Flanges

DIN and ANSI from DN 50

- material

1.4571, 1.4571 with Hastelloy C4 plated
DN 50 PN 40 steel enamelled

Tuning fork

Material

1.4581, Hastelloy C4, Hastelloy C4 enamelled
1.4581 with Säkaphen or ECTFE plated

Extension tube (VEGASWING 83 W5 Ex)

Material

1.4571, Hastelloy C4, Hastelloy C4 enamelled
1.4571 with Säkaphen or ECTFE plated

Length
- 1.4571, Hastelloy C4

200 mm … 4000 mm

- Hastelloy C4 enamelled

200 mm … 1200 mm

- 1.4571, Halar

200 mm … 1200 mm

- 1.4571, Säkaphen

200 mm … 4000 mm

Weight

Plastic housing

approx. 1,5 kg

Tube extension

approx. 0,11 kg/m (VEGASWING 83 W5 Ex.C)

Ambient conditions

Ambient temperature on housing

-40

°

C … +65

°

C

Storage and transport temperature

-40

°

C … +70

°

C

Medium temperature

-40

°

C … +100

°

C

Medium temperature with temperature
adapter of 1.4571 (option)

-40

°

C … +130

°

C

Operating pressure

Operating pressure

max. 25 bar
(VEGASWING 83 W5 Ex.C: with locking
ARV2EX0.C… to 4 bar, otherwise unpressurized)

Test pressure

max. 40 bar