c) Continue to check each coulter electrode in succession, left to right.
d) If any coulter electrode exhibits no continuity or resistance higher than 2 ohms, refer

to the maintenance or trouble shooting sections for possible causes.


Note: It is advisable to perform this test on a routine basis (weekly or every 20-25 hours
of data collection) to ensure you are obtaining reliable data.

4) Hitch height

—adjust hitch on implement so implement operates level when coulter

electrodes are 1-

2” in the soil. The hitch is designed with four possible height positions.











Maintenance and Lubrication

Proper maintenance and lubrication of the Veris Soil Sensor Cart will greatly extend the useful life of
the unit, and Veris Technologies strongly suggests that you follow the following guidelines:

LUBRICATION


Rockshaft pivot points

Each pivot (located at the left, center, and right) contains
an upper and lower grease zerk. Due to the limited motion of the
rockshaft, these should be lubricated on 40-hour intervals. This may
vary based on the number of times the unit is raised and lowered.