background image

Veris Technologies

Pub. #OM 1CM02-1

10


grease zerk


Hubs --

Use good quality wheel bearing or lithium grease for lubrication, but we

suggest that you grease the hubs sparingly. Over-lubricating the hub

will result in pre-mature seal failure, and an excessive amount of grease

in the hub cap/commutator. On an interval of 150 hours, 1-2 strokes of

grease should be sufficient.


Grease zerk




ADJUSTMENTS

Commutators-- The spring-loaded commutators are located in the center of each coulter

electrode hub cap. They are factory preset, and should not need

routine adjustment. If a continuity test shows abnormally high resistance,

the commutators should be checked. This may be performed in the following

manner:

1)

Remove the 3/8” allen head set screw.

2) Remove the commutator by turning counter-clockwise.
3) Depress the spring loaded tip on a hard surface to determine if

plunger has adequate tension and can move freely.