Series – Ohaus RANGER 3000 COMPACT SCALES Manual User Manual
Page 36
EN-34
Ranger™ 3000
Series
7.5 Output Format
Weight string print format:
Field
Weight space Unit
space Stability space G/N
Space Term. Char(s)
Length 9
1
5
1
1
1
NET
1
Each field is followed by a single delimiting space (ASCII: 32)
Definitions:
Weight
- Up to 9 characters, right justified, - at immediate left of most significant character
(if negative).
Unit
- Up to 5 characters, left justified. If the Unit in the Print Content menu was set to
OFF, the unit will be removed in the weight string and replaced by spaces.
Stability
- “?” character is printed if not stable. If weight is stable neither “?” or following
space is printed.
G/N
- “NET” printed if weight is net weight, ‘G’ or nothing printed if weight is a gross
weight.
Terminating Character(s) - terminating character(s) printed depending on FEED menu setting.
7.6 Compliance
Compliance to the following standards is indicated by the corresponding mark on the product.
Mark
Standard
This product conforms to the EMC Directive 2004/108/EC, the Low
Voltage Directive 2006/95/EC and the Non-Automatic Weighing
Instrument Directive 2009/23/EC.
The Declaration of Conformity is available online at
europe.ohaus.com/europe/en/home/support/compliance.aspx.
AS/NZS CISPR 11
CAN/CSA-C22.2 No. 61010-1-12, UL Std. No. 61010-1 (3
rd
edition)
Important notice for verified weighing instruments
Weighing Instruments verified at the place of manufacture bear one of the
preceding marks on the packing label and the green ‘M’ (metrology) sticker on the
descriptive data plate. They may be put into service immediately.
Weighing Instruments to be verified in two stages have no green ‘M’ (metrology) on
the descriptive data plate and bear one of the preceding identification marks on the
packing label. The second stage of the initial verification must be carried out by an
authorized and certified service organization established within the European
Community or by the National Notified Body.
The first stage of the initial verification has been carried out at the manufacturers work. It
comprises all tests according to the adopted European standard EN 45501:1992, paragraph
8.2.2.
If national regulations limit the validity period of the verification, the user of the weighing
instrument must strictly observe the re-verification period and inform the respective weights
and measures authorities.