3.6 Counting with automatic reference determination
Prerequisite
A-SMPL ON is set in the menu.
➜
Place the number of pieces displayed above the key
Sample Size
into the
The scale automatically determines the average piece weight and then shows the
quantity.
The rest of the counting process is as described earlier.
3.7 Counting with two scales
For piece counting, it is possible to connect a second scale or weighing platform, e. g.
a floor scale for counting a large number of pieces via the optional analog second
scale interface.
The necessary settings for the application and interface parameters are described in
the Sections 4.4.1, 4.6.1 and 4.6.4.
3.7.1
Counting with a reference scale
Prerequisite
The connected second scale is configured as reference scale.
1. Place the reference parts on the reference scale and press
Sample 10 or
The scale determines the average piece weight and changes to the display in
pieces (PCS).
2. Place the parts to be counted on the first scale.
The total quantity is displayed.
Note
•
If tOtAL-Ct -> bULK is set in the menu, only the number of pieces on the bulk
scale is displayed.
•
If tOtAL-Ct -> bOtH is set in the menu, the reference quantity is added to the
bulk quantity.
container.
Sample Size.