4
Use this information to plan your Linear Encoder
installation.
• Mount the linear encoders close to machine guide ways to
ensure system accuracy.
• Space between reading head casting and mounting bracket
or surface must not exceed [.188”] 4.7mm.
Mounting Information
• Allow clearance for alignment bracket removal.
•
Alignment brackets must not be removed until
instructed.
End of scale clearance requirements
• [1.0] 25mm of clearance is required above the scale case
top surface for access to the expansion cover fasteners.
• A minimum clearance of [5.0] 127mm is required at each
end of the scale case.
• Mount encoder in a horizontal or vertical position as shown.
• Do not mount flat or inverted.
Horizontal
mounting
Vertical
mounting
[1.0]
25mm
[5.0]
127mm
[1.0] 25mm
[1.0]
25mm
[5.0]
127mm
Alignment bracket removal clearance
Alignment bracket
(2)