Use this information to plan your Linear Encoder
installation.

• Mount the linear encoders close to machine guide ways to

ensure system accuracy.

• Space between reading head casting and mounting bracket

or surface must not exceed [.188”] 4.7mm.

Mounting Information

• Allow clearance for alignment bracket removal.

Alignment brackets must not be removed until

instructed.

End of scale clearance requirements

• [1.0] 25mm of clearance is required above the scale case

top surface for access to the expansion cover fasteners.

• A minimum clearance of [5.0] 127mm is required at each

end of the scale case.

• Mount encoder in a horizontal or vertical position as shown.
Do not mount flat or inverted.

Horizontal

mounting

Vertical

mounting

[1.0]

25mm

[5.0]

127mm

[1.0] 25mm

[1.0]

25mm

[5.0]

127mm

Alignment bracket removal clearance

Alignment bracket

(2)