ACU-RITE ENC 250SS User Manual
Page 13
Acu-Rite Companies Inc.
ENC 250™
SINGLE SECTION
11
• Remove red plastic plug.
• Insert the thumb screw through the washer, compression
sleeve, and into the end cap hole.
• Thread the screw into the holder inside the end cap, but do
not tighten.
End Cap
Remove plastic plug
Compession sleeve
Thumb screw
Washer
• Completely loosen the M5 SHSS, but do not remove.
• Position the readout so that it can be seen while adusting
the thumb screw head.
• Insure that the readout is in metric mode.
M5 SHSS
Thumb screw
• Tighten the screw until the readout display reads
approximately .05mm.
• Back off the screw until the display stops changing.
• Reset readout to zero and repeat the procedure two more
times. This relaxes the tape before setting the tension.
Thumb screw
• Refer to the tensioning value listed on the label on the case.
• Slowly tighten the screw until the display reaches the tensioning
value.
• Fully tighten the M5 SHSS [30-lb-in] 3.4N m.
M5 SHSS
Thumb screw
Encoder Installation Procedure