Acu-Rite Companies Inc.
ENC 250™
SINGLE SECTION
Cover plate
T-10 Torx screw (2)
Plug
• Determine the cable exit direction before installing the encoder.
• To change the cable exit direction; remove the cover plate
and rotate the cable 180°.
Mounting Preparation
Changing cable exit direction ...
Please follow these preparation guide lines.
• Understand your mounting requirements.
• Mount with lip seals down and away from the work area.
• Brackets should be kept as short as possible and rigid.
• Surfaces must be in good condition, clean, and free of dirt.
Remove paint from machined mounting surfaces.
•
Alignment brackets must only be removed as
instructed.
Armor cable hex crimp
Measuring length ...
• Machine travel can not exceed the encoder measuring length.
• Either limit machine travel or obtain correct length scale.
• Encoder lip seals to face away from coolant spray.
3
“L”
Coolant spray ...
“L” = Measuring length + [2.0”] 50.8mm nominal over travel
Travel is limited by stops at each end of scale
[1.0”]
25mm
[2.8”]
71.1mm