• Remove the thumb screw, sleeve, and washer.
• Apply silicone grease to the plug and reinstall it.
12
Apply silicone grease to plug
and reinsert it
• With the readout properly mounted, route the cable with
sufficient slack loops for machine movement to the readout.
• Secure cables by fastening with clips or ties.
• Attach the encoder connectors to the readout.
Electrical shielding ...
• Connect a ground wire from the terminal on the back of
the readout to the machine or earth ground.
• Attach a ground wire from the machine to a solid earth
ground.
• With the encoder attached to the cable connected to the
readout, check shielding by measuring resistance between
connector housing and scale unit.
Desired value: 1 ohm max.
Encoder Installation Procedure