• Remove the thumb screw, sleeve, and washer.
• Apply silicone grease to the plug and reinstall it.

12

Apply silicone grease to plug

and reinsert it

With the readout properly mounted, route the cable with

sufficient slack loops for machine movement to the readout.

Secure cables by fastening with clips or ties.
Attach the encoder connectors to the readout.

Electrical shielding ...

Connect a ground wire from the terminal on the back of

the readout to the machine or earth ground.

Attach a ground wire from the machine to a solid earth

ground.

With the encoder attached to the cable connected to the

readout, check shielding by measuring resistance between
connector housing and scale unit.
Desired value: 1 ohm max.

Encoder Installation Procedure