Insert the encoder into the spar.

• Center the encoder from end to end with the spar.

• Lock in place by tightening the M4 set screws.

Attach the bracket to the machine.

• Align the reading head mounting holes with the bracket holes.

• Attach head to bracket / Set leveling screws / Secure fasteners.

To locate the reading head bracket, attach it to the reading head.

• Center the axis and mark the bracket mounting holes.

• Remove the bracket, drill / tap holes for 1/4-20 (M6).

M4 x 8mm set screws

8-32 x 5/8” SHCS

(M4 x 16mm)

Do not tighten prior to adjusting

leveling set screws.

Reading head bracket

8-32 x 5/8” SHCS

(trim if necessary)

SENC 150

Spar Installation Procedure

Slide the brackets away from the reading head.

• Remove the alignment brackets and save for future use.

• Proceed to page 13, “Checking Your Installation”.

Alignment bracket

removal

Slide brackets away from reading head and cable.

Twist 45°

13

ACU-RITE

®

516291-21_Ve00_SENC_150.indd 15

10/22/2009 10:00:45 AM