Mounting Requirements
SENC 150
Mounting options can be adapted to machine mounting surfaces
using spacers, standoffs, or leveling set screws.
• Measuring length and mechanical configuration of your
machine determine your options.
• Backup spar mounting is an option but not required for lengths
up to 60”.
• Fastener lengths described on this page are included with the
encoder or the backup spar.
• Less than 24” : Use end mounting holes.
• Over 60” : A backup spar is required.
1/4-20 x 1” BHCS
& scale washer (supplied)
End hole mounting
1/4-20 x 1/2” BHCS
& spar washer (supplied)
Backup spar mounting
• 24” to 60” : Use end mounting holes with center support.
.94 [23.8]
1/4-20 x 1” BHCS
Typical (supplied)
1/4-20 x 3/4” SHCS
Scale
washer
Center support
End hole mounting
with center support
M4 x 8mm SHSS
(supplied)
Support washer
8
ACU-RITE
®
516291-21_Ve00_SENC_150.indd 10