These steps apply to all spar mounting conditions.

ACU-RITE

®

bracket kit instructions supercede this section.

• Adjust drill depths and fastener lengths as required.

• When instructed on page 12: Adjust the leveling set screws as

follows:

1. Insert, but do not tighten 8-32 (M4) reading head screws.

2. Place a .001”-.003” shim between the leveling set screws

and mounting surface.

3. Adjust each set screw until a slight drag is felt on the shim.

4. Evenly tighten the 8-32 (M4) reading head mounting screws.

• Contact your Authorized Distributor should you require

additional assistance.

• Move the axis to its center of travel.

• Mark the axis for quick return to center.

• Determine encoder cable exit direction and adjust (

see page

3).

• Drill / tap the first end mounting hole / attach the spar.

• Align to within .010” TIR. to -A-, drill / tap second end hole.

• Attach the spar / align to within .010” TIR. to -A-.

• Locate the spar with the underside flush with the axis parting

line.

• Mark one end mounting hole location.

Spar Installation Procedure

SENC 150

Align to within .010” TIR of -A-

Align top of spar to within

.015” of -A-

-A- = Axis travel

Axis parting line

-A- = Axis travel

1/4-20 x 1/2” BHCS &

Flat washer .017” thk.

End mounting hole (typical)

Center mounting axis

Mark center of travel