B. new battery installation – ACR&Artex C406-1 User Manual
Page 77
25-62-10
Page 77 of 90
JUL 31/12
ACR ELECTRONICS, INC / ARTEX PRODUCTS
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
C406-1 (453-5002), C406-1HM (453-5003)
SUBTASK 25-62-10-450-002
B. New Battery Installation
CAUTION:
DO NOT USE CONTACT CLEANER ON ELT COMPONENTS. SUCH CHEMICAL AGENTS
CAN BE HIGHLY DESTRUCTIVE TO THE MOUNTING HARDWARE AND ELT HOUSING,
CAUSING CRACKING, FRACTURING AND OTHER DAMAGE.
(1)
This subtask applies to installation of a new (i.e., replacement) battery.
(2)
Verify the bottom of the ELT is clean and free of battery corrosion residue. Clean as
necessary.
(3)
Remove the paper backing from the rubber seal at the connector end of the battery pack.
(4)
Perform the procedure outlined in SUBTASK 25-62-10-450-001, on page 75.
(5)
Place a new battery expiration date label on the ELT mounting frame cap or other visible
location.
NOTE: The new label is supplied with the new battery pack.
(6)
Enter the pertinent battery replacement information in the logbook (i.e., aircraft records) and
fill out any other required documentation.