25-62-10

Page 39 of 90

JUL 31/12

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-1 (453-5002), C406-1HM (453-5003)

TASK 25-62-10-750-802

2. Inspection and Test Procedures

SUBTASK 25-62-10-990-001

A. Checklist

(1)

Table 5 provides a list of the ELT inspection and testing requirements, a copy of which may be

used as a checklist to verify inspection and test completion. The item numbers in the table

correspond to the item identifiers for each task.

NOTE: Items 5a through 5h are mandatory requirements only in Canada, in addition to

meeting the other inspection and test requirements listed in Table 5.

Table 5. ELT Inspection and Test Checklist

ITEM NO.

DESCRIPTION

BY

1

Coax Cable and Wiring Connections Inspection

2

ELT Mounting Tray and Hardware Inspection

3

ELT Battery Pack Inspection

4

G-Switch Functional Check

5a

121.5 MHz Frequency Measurement

5b

Audio Modulation Check

5c

121.5/243.0 MHz Power Output Measurement

5d

406 MHz Frequency Measurement

5e

406 MHz Power Output Measurement

5f

Current Draw Test

5g

Digital Message Verification

5h

ELT Reset Check

6

Installed Transmitter Test

7

Antenna Test

8

Inspection and Test Documentation