beautypg.com

Remote switch, A. location, Figure 18. remote switch outline and dimensions – ACR&Artex C406-1 User Manual

Page 63: B. installation

background image

25-62-10

Page 63 of 90

JUL 31/12

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-1 (453-5002), C406-1HM (453-5003)

TASK 25-62-10-450-803

4. Remote Switch

SUBTASK 25-62-10-450-001

A. Location

NOTE: This procedure is applicable to the most commonly used remote switch (345-6196-04). If

an optional switch is installed in lieu of this one, the applicable installation instructions

should be consulted.

(1)

Select a suitable location for the remote switch assembly.

(2)

The switch assembly must be mounted in the cockpit where the pilot can easily reach the

switch and see the LED.

(3)

The switch assembly requires a space approximately 2.0 x 1.3 in. (51 x 33 mm) on the panel

surface and behind the panel. See "Figure 18. Remote Switch Outline and Dimensions".

Figure 18. Remote Switch Outline and Dimensions

SUBTASK 25-62-10-450-002

B. Installation

(1)

Mark the cutout on the cockpit panel. See "Figure 18. Remote Switch Outline and

Dimensions".

(2)

Fit the switch assembly into the cutout and mark the four screw holes, then remove the

switch.

(3)

Drill the screw holes with a #28 or 3.6 mm drill.

(4)

Install the switch assembly using the 4-40 x ½ in. pan head screws, nuts and lock washers

provided in the remote switch installation kit (455-6196).

NOTE: Step 4 may be accomplished after wiring is completed and the harness plug has been

plugged into the switch assembly in accordance with the requirements of SUBTASK

25-62-10-450-010, on page 71. If such is the case, perform a fit check at this time.

(5)

Apply the “For Aviation Emergency Use Only/Unauthorized Use Prohibited” placard (591-

0428), provided in the installation kit, as close to the switch as practical.

1.10

(28)

0.044

(1.1)

0.140

(3.6)

1.59

(40)

OUTLINE OF REMOTE
SWITCH BODY

0.1405 (3.57) Ø
USE #28 (3.6) DRILL
(4 PLCS)

NOTE: HATCHED AREA
IS CUTOUT PATTERN

1.04

(26)

1.73
(44)

1.30

(33)

2.00

(51)

1.20

(30)

0.50

(13)

1.70
(43)

1.06

(27)

1.45

(37)

FRONT VIEW

SIDE VIEW

HOLE CUTOUT GUIDE FOR INSTALLATION

OF 345-6196-04 (FRONT VIEW)

RECOMMENDED

CUTOUT PATTERN

DIMENSIONS IN INCHES (MM)

ARTEX

ON

ARM

Press ON

Wait 1 Second

Press ARM

EMERGENCY USE ONL

Y

Test/Reset

ELT

TOLERANCE: ±0.03 (1)

This manual is related to the following products: