beautypg.com

B. electrical, Table 3. electrical specifications – ACR&Artex C406-1 User Manual

Page 34

background image

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-1 (453-5002), C406-1HM (453-5003)

25-62-10

Page 34 of 90

JUL 31/12

SUBTASK 25-62-10-870-002

B. Electrical

(1)

Table 3 lists the electrical specifications of the C406-1 Series ELT.

Table 3. Electrical Specifications

CRITERIA

PARAMETER

CHARACTERISTIC

Operating Frequencies

406.025 MHz

± 2 KHz (Initial)

± 5 KHz (5 years)

2 parts/10E9 in 100 ms

406.028 MHz, or higher

± 1 KHz

121.5 and 243.0 MHz

± 0.005%

Modulation

406 MHz

Bi-Phase L (G1D)

121.5 and 243.0 MHz

Amplitude Modulation (A3X)

Transmitter Duty Cycle

406 MHz

440 ms (± 1%), or

520 ms (± 1%), every

50 seconds (± 5%)

121.5 and 243.0 MHz

Continuous

Peak Effective Radiated

Power (PERP)

406 MHz

5 W (37 ± 2 dB) PERP, or

EIRP for 24 hrs @ -20° to +55° C

121.5 and 243.0 MHz

Min. 50 mW (17 dBm) PERP for 50 hrs

@ -20° to +55° C or 100 mW EIRP

(20 dBm) for 48 hrs @ -20° to +55° C

Occupied Bandwidth

406 MHz

20 KHz max.

121.5 and 243.0 MHz

25 KHz max.

Spurious Emissions

406 MHz

Per RTCA/DO-204

121.5 and 243.0 MHz

Per CFR Title 47 (FCC), Part 87

Battery

Type of Cell

Lithium Manganese Dioxide

Voltage

12.0

Amp-Hour Rating

10.0

This manual is related to the following products: