beautypg.com

Figure 3. cockpit remote switch, Figure 4. buzzer, Figure 5. battery pack assembly – ACR&Artex C406-1 User Manual

Page 29

background image

25-62-10

Page 29 of 90

JUL 31/12

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-1 (453-5002), C406-1HM (453-5003)

(2)

The cockpit-mounted remote switch assembly is comprised of an ELT status LED and control

switch, which allows an operator to monitor ELT status and manually turn on the ELT (i.e.,

activate) for testing and reset (i.e., deactivate) the ELT. See "Figure 3. Cockpit Remote

Switch".

NOTE: The ELT CANNOT be disarmed or disabled from the cockpit. Cockpit operation is

limited to deactivating or manually activating the ELT.

Figure 3. Cockpit Remote Switch

(3)

The buzzer (i.e., horn) provides an audible alert when the ELT is active. See "Figure 4.

Buzzer".

Figure 4. Buzzer

(4)

The battery pack for the C406-1 Series ELT consists of four “D” size lithium manganese

dioxide cells connected in series. To prevent the cells from being charged, diodes are

connected across each cell and fuses are connected to the output. See "Figure 5. Battery Pack

Assembly".

Figure 5. Battery Pack Assembly

ARTEX

ON

ARM

Press ON

Wait 1 Second

Press ARM

EMERGENCY USE ONL

Y

Test/Reset

ELT

LED

SWITCH

This manual is related to the following products: