Mounting tray, A. location – ACR&Artex C406-1 User Manual
Page 57
25-62-10
Page 57 of 90
JUL 31/12
ACR ELECTRONICS, INC / ARTEX PRODUCTS
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
C406-1 (453-5002), C406-1HM (453-5003)
TASK 25-62-10-450-801
2. Mounting Tray
SUBTASK 25-62-10-450-001
A. Location
CAUTION:
MANY ORIGINAL ELT INSTALLATIONS ARE INADEQUATE AS FAR AS UNIT LOCATION
AND SURFACE RIGIDITY ARE CONCERNED. BECAUSE OF THE CRITICAL FUNCTION AN
ELT PERFORMS, IT IS IMPORTANT THE INSTALLATION FOLLOWS THE INSTRUCTIONS
AND RECOMMENDATIONS HEREIN.
CAUTION:
THE MOUNTING SURFACE MUST BE EXTREMELY RIGID; THEREFORE, MOUNTING AN
ELT DIRECTLY TO THE AIRCRAFT SKIN IS UNACCEPTABLE. MOUNTING THE ELT
DIRECTLY TO THE AIRCRAFT SKIN INDUCES “CRASH HIDING” VIBRATIONS AND
PROVIDES A VERY POOR MOUNTING SURFACE.
CAUTION:
AVOID LOCATING THE ELT WHERE IT WILL BE SUBJECTED TO UNPROTECTED
EXPOSURE TO HARSH CHEMICAL FLUIDS SUCH AS DEICING COMPOUNDS. THESE
TYPES OF CHEMICAL FLUIDS CAN PROMOTE CRACKING AND FRACTURING OF THE
ELT MOUNTING FRAME AND HOUSING COMPONENTS BY DEGRADING THE
STRUCTURAL INTEGRITY OF THESE COMPONENTS. THESE SAME CHEMICAL AGENTS
MAY ALSO CAUSE CORROSION OF ELECTRICAL CONNECTIONS.
(1)
Select a suitable location for the mounting tray. See "Figure 14. C406-1 Series ELT Outline and
Dimensions". Refer to these dimensions when determining mounting location.
Figure 14. C406-1 Series ELT Outline and Dimensions
FLIGHT
5.21
(132)
1.71
(43)
11.63
(295)
5.50
(140)
3.42
(87)
2.00
(51)
3.76
(96)
3.90
(99)
0.165 (4.2) Ø MOUNTING
HOLES (4 PLCS)
Dimensions in inches (mm)
NOTE: Allow a minimum of
5 inches (127 mm) of clearance
in front of the mounting frame cap
to facilitate cap removal.