Communications port, Power – Zebra Technologies Mobile Printer User Manual
Page 30
O-30
Cameo 2/3 Series User Guide
8
7
6
4
2
1
5
3
Communications Port
Pin
Pin
Signal
Signal
Number
Name
Type
Description
1
RXD
input
Receive Data
2
TXD
output
Transmit Data
3
CTS
input
Clear To Send from host
4
RTS
output
Request To Send
set high when printer is
ready to accept command/
data
5
GND
Ground
6
NC
No Connect
7
DSR
input
Data Set Ready: Low to high
transition turns printer on,
High to low transition turns
printer off (if enabled)
8
DTR
output
Data Terminal Ready
high when printer is on (set at
battery voltage for “S” option)
Power
Cameos utilize removable NiMH battery packs. If not connected to a
terminal with DTR present, the Cameo will automatically power off to
conserve battery life. The time-out value can be programmed from
the host terminal; the factory default time-out is two minutes.
Additional power features include:
• Low battery indicated by flashing LED and reported to terminal on demand
• Power On/Off controlled from terminal or keypad
Communications Port (8 pin Circular DIN)