Xantrex Technology XPD 60-9 User Manual
Page 48
![background image](/manuals/230606/48/background.png)
Section 3. Local Operation
User Diagnostics
46
Operating Manual for XPD Series Power Supply
Table 3.2 User Diagnostics
Symptom
Check
Further Checks and Corrections
No output and the
display is blank.
In input voltage within
specified range?
Connect to appropriate voltage
source. See
Power switch ON?
Turn on power.
Internal circuit?
See your service technician.
No output but the
display turns on.
OVP LED turned on?
See
Front panel S/D LED
turned on?
See
Current limit set to zero?
See
Voltage control set to
zero?
REM LED turned on?
If using remote analog control,
check your analog programming
source (See
).
Internal circuit.
See your service technician.
Output voltage not
adjustable.
Is unit in current limit
mode? (Red Current
Limit mode LED turned
on.)
Turn current knob clockwise to
increase current limit. Reduce load
if current is at maximum. See
“Standard Operation” on page 35
.
Is unit in remote
programming mode?
(Green PGM LED is
turned on.)
If using remote analog control,
check your analog programming
source (See
). If not, refer to your
digital interface manual.
Is unit at maximum
voltage or current limit?
Reduce load for lower voltage or
current requirement.