beautypg.com

Positive-negative supply, Note – Xantrex Technology XPD 60-9 User Manual

Page 46

background image

Section 3. Local Operation
Using Multiple Supplies

44

Operating Manual for XPD Series Power Supply

Positive-negative supply

To obtain a positive-negative supply, connect the

negative output terminal of one supply to the positive terminal of the second supply.
The positive output terminal of the first supply now provides a positive voltage
relative to the common connection. The negative output terminal of the second
supply provides the negative voltage. The current limits can be set independently of
each other. The maximum current available in split operation is equal to the rated
output of the supplies.

Figure 3.5 Split Supply Operation of Multiple Supplies (Positive-negative Supply)

Load Lines

Use the largest gauge and
shortest length possible

Positive Load

Terminal

Common Load

Terminal

Negative Load

Terminal

Load

Power Supply 2

Power Supply 1

Postive Sense

Positive Output

Terminal

Negative Output

Terminal

Return Sense

Postive Sense

Positive Output

Terminal

Negative Output

Terminal

Return Sense

Note

Split supply operation requires the use of an isolated analog interface card on the

slave unit. In this arrangement, one-knob control of both supplies is possible

This manual is related to the following products: